Hemolysis interference in the determination of 25 biochemical constituents using ADVIA 1800 autoanalyzer
DOI:
https://doi.org/10.15381/anales.v76i4.11407Keywords:
Hemolysis, Hemolysis Interference, Bias, Systematic.Abstract
Introduction. Hemolysis interference is the main cause of pre analytical rejection of serum samples in clinical laboratory. Objectives. To identify and quantify possible hemolysis interferences in the routine measurement of 25 biochemical constituents using ADVIA 1800 autoanalyzer, by clinical relevant interference criterion when the maximum desirable systematic error is exceeded. Design. Comparative descriptive study. Institution. Hospital Edgardo Rebagliati Martins, EsSalud, Lima, Peru. Biologic material. Blood samples collected from volunteer subjects. Interventions. Increasing amounts of hemoglobin (0.26 g/L, 0.53 g/L, 1.05 g/L, 2.10 g/L, 3.25 g/L, 4.30 g/L, and 5.25 g/L) were added to seven different aliquots of sera mixture and influence of interfering influence in 25 constituents was determined by duplicate. The Spanish Society of Clinical Chemistry protocol was followed. Main outcome measure. Hemolysisrelated relative percentage deviation of the constituent concentration compared with the sample without interference. Results. Urea, creatinine, uric acid, total bilirubin, HDL cholesterol, LDL cholesterol, triglycerides, calcium, and gamma glutamyl transferase showed no interference. Interference was observed for glucose, protein, albumin, cholesterol, potassium, phosphorus, magnesium, lactic dehydrogenase, creatine phosphokinase, aspartate aminotransferase, alanine aminotransferase, lipase, sodium, chlorine, alkaline phosphatase and amylase. Conclusions. Out of 25 constituentss studied, 16 had clinical significant interference. It is recommended that each laboratory investigate this interference effects using their own methods, reagents or instruments.Downloads
Published
2015-12-31
Issue
Section
Artículo Original
License
Copyright (c) 2015 Italo Moisés Saldaña O.

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Those authors who have publications with this magazine accept the following terms:
- Authors will retain their copyrights and guarantee the journal the right of first publication of their work, which will be simultaneously subject to Creative Commons Attribution License that allows third parties to share the work as long as its author and its first publication this magazine are indicated.
- Authors may adopt other non-exclusive licensing agreements for the distribution of the version of the published work (eg, deposit it in an institutional electronic file or publish it in a monographic volume) provided that the initial publication in this magazine is indicated.
- Authors are allowed and recommended to disseminate their work over the Internet (eg: in institutional telematic archives or on their website) before and during the submission process, which It can produce interesting exchanges and increase quotes from the published work. (See El efecto del acceso abierto ).
How to Cite
1.
Saldaña O. IM. Hemolysis interference in the determination of 25 biochemical constituents using ADVIA 1800 autoanalyzer. An Fac med [Internet]. 2015 Dec. 31 [cited 2025 Jun. 5];76(4):377-84. Available from: https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/11407