Industrial Wastewater Treatment and Sanitary Management System Optimization for Class III Water discharge from pithead level 250 (EF 03) to the San José River, Peru

Authors

  • Adán Puente Rodríguez Universidad Nacional Mayor de San Marcos. Lima, Perú
  • Julia Calderón Celis Universidad Nacional Mayor de San Marcos. Lima, Perú

DOI:

https://doi.org/10.15381/idata.v21i2.14916

Abstract

The main objective was to manage the implementation of standards, procedures and legal requirements in order to optimize the industrial wastewater treatment system of the Huarón Mine in Peru. Furthermore, to ensure the quality of class III water discharges. The results obtained were satisfactory; a final pH of 8.02 with a dosage of 100 gr/m3 (Cal) and a reduction of zinc metal content below 2.5 ppm were achieved.

Downloads

Download data is not yet available.

Author Biographies

  • Adán Puente Rodríguez, Universidad Nacional Mayor de San Marcos. Lima, Perú

    Ingeniero de Minas, Egresado Maestría en gestión integrada en seguridad, salud ocupacional y medio ambiente Universidad Nacional Mayor de San Marcos, consultor independiente.

  • Julia Calderón Celis, Universidad Nacional Mayor de San Marcos. Lima, Perú

    Doctora, Docente - Investigadora de la Universidad Nacional Mayor de San Marcos. Auditor en Sistemas de Gestión de Seguridad y Salud en el Trabajo. RD. N° 54-2015-MTPE/1/20.3

Downloads

Published

2018-12-20

Issue

Section

Diseño y Tecnología

How to Cite

Industrial Wastewater Treatment and Sanitary Management System Optimization for Class III Water discharge from pithead level 250 (EF 03) to the San José River, Peru. (2018). Industrial Data, 21(2), 7-16. https://doi.org/10.15381/idata.v21i2.14916